الدكتور/ مصطفى عراقى - Dr.Mostafa Eraqi

أستاذ مساعد الميكروبيولوجى والمناعة بكلية العلوم

احهزة المعامل


Elecsys 2010

Automated electro – chemiluminescense system
For thyroid & reproductive functions, first result obtained after 12 minutes; then a result every 20 seconds
Various hormonal assays, TDM and tumor markers
Can perform up to 180 tests/hour



(Axsym (Version 6.1) (Abbott)


Immunology Autoanalyzer
Fully automated system, performing both random and continuous immunoassays. Using 3 different assays technologies:
1- MEIA 2- FPIA 3- REA ( Radioactive Energy Attenuation)
Can perform 56 different parameters as: TORCH, Hepatitis Markers, HIV Test, Tumor Markers, Hormonal Assays and Drug Assays
Sensitivity is equal to 99.69%
Can perform up to 130 specimens/hour


Cell Dyn 1800


The Cell Dyn is the latest 3-part differential analyzer. Offering 18 parameters and extensive QC and data management capabilities, the Cell Dyn 1800 meets the needs to today's growing labs
The system utilizes impedance resistance to measure human cells while incorporating the patented von Behrens plate to virtually eliminate coincidence counts from each sample
Throughput of up to 60 samples/hour
Bar code reader eliminates transcription and data entry errors


Immulite 1000


The Immulite 1000 immunoassay system features an extensive menu, ease of use, reliability, robust hardware and excellent assay performance
The IMMULITE 1000 performs various types of immunoassay testing for cardiac biomarkers, thyroid function, reproductive endocrinology, infectious disease, TDM, serology, anaemia, drugs of abuse, diabetes and tumor markers are all easily run with true random access capability
Turbo capabilities provide results in 15 minutes for critical STAT assays including the cardiac biomarkers Troponin I, CK-MB and Myoglobin, as well as Intact PTH and HCG
The Immulite 1000 is designed to meet the immunoassay testing needs of the clinical laboratory today and tomorrow


(Stratagene (Real Time PCR)


Real Time PCR technology reduced the time
needed to perform tests into 2-3 hours. The machine do the amplification and detection procedure of the PCR technique.
The technique is used to do the following tests:
HBV- DNA by PCR
HCV- RNA by PCR
HCV Genotyping
CMV by PCR
HIV by PCR
HLA - DR
HLA B27
TB DNA by PCR
Philadelphia Chromosome by PCR
Factor V (Leiden Mutation) by PCR
Familial Mediterranean Fever (FMF) by PCR (12 mutations)
Genetic Testing for the Oral Anticoagulant Therapy Dose
Genetic Testing for Thalassaemia

Coulter HmX


The Coulter HmX hematology analyzer offers three-dimensional VCS technology, providing excellent sensitivity, specificity and efficiency in white cell differential and reticulocyte analysis.

Pathology Unit

The pathology unit is equipped with: fully
automated specimen processing machine, microtome, tissue path and Olympus microscope. The unit launched, in 2008, the service of immunohistochemical staining of about 120 different stains.


(Rotagene (Real Time PCR)


What sets the Rotor-Gene apart is its amazing precision; the result of near-perfect well-to-well thermal and optical uniformity. Its design also enables a fast data acquisition rate, a capability now proving to be essential for advanced applications such as HRM (high-resolution melt).
Software: Build-in extensive analysis, graphing and statistical functions.
It supports the broadest range of applications, including quantification, HRM, end-point, association/disassociation (i.e. melting/annealing) kinetics, and nucleic acid concentration measurement.
It has the greatest optical range, with 6 channels spanning UV to infra-red wavelengths.

(Computerized Assessed Semen Analysis (CASA


This method allows objective semen analysis and fully validated technology. The following elements of semen analysis are accurately assessed: sperm concentration, % motility, motility grading (in agreement with the World Health Organization Laboratory Manual for the Examination of Human Semen), concentration of grade (a), (b), (c) and (d) motile spermatozoa, as well as morphology and motility characteristics including velocity, linear velocity and linearity

Synchron CX-7 (Beckman)

State of the art
technology.
Fully automated auto analyzer utilizing liquid chemistry technique.
STAT result capability, urgent results can be delivered in few minutes.
700 tests/hour.
Bar coding of samples and reagents to avoid any mixing of samples.

X-Tractor Gene

X-Tractor Gene machine is the most recent technology that was added to Saridar Laboratory. The machine do the extraction process of the DNA in the PCR test automatically and this helps in:
1- Prevent the cross contamination that can results from manual extraction
2- Regulates the steps of the extraction without any human interferance and this prevents error that may occur
3- Decrease the duration needed to finish the extraction process as it can do extraction for 96 samples at the same time so decreasing the time of the PCR test


(Synchron CX-9 pro (Beckman)

State of the art technology.
Fully automated auto analyzer utilizing liquid chemistry technique.
STAT result capability, urgent results can be delivered in few minutes.
700 tests/hour.
Bar coding of samples and reagents to avoid any mixing of samples.

Sysmex K21


A fully automated 18 parameters hematology analyzer with 3 differential WBCs parameters.

RBCs, WBCs, Platelet count and MCV are calculated using a very sensitive technique called ''aperture impendence method".

Haemoglobin is measured by a very sophisticated single beam photometer.

Haematocrite, MCH and MCHC are calculated by and computed by the machine from the previous estimated values.

(Architect Cell (Abbott


The Architect c4000 is integrated with the Architect i1000SR to consolidate clinical chemistry and immunoassay on one platform
Robotic Sample Handler (RSH) maximizes analytical productivity with "real time" STAT, automated rerun, and reflex testing capabilities
Multiple sample loading
Up to 55 assays onboard including ISEs allows consolidation of testing
Opencode system provides flexibility to run esoteric assays
Immediate and consistent STAT processing with turn around


جامعة المجمعة

Biology Department


أرقام الاتصال

 

جوال: المملكة العربية السعودية:   00966565709849
جمهورية مصر العربية:               00201005111249
هاتف المكتب  :                         0096664044088
تحويلة داخلية:                            4088

البريد الالكترونى: [email protected]

الساعات المكتبية


من الاحد الى الخميس : 12 الى 1


اعلانات

سوف تعقد الاختبارات الالكترونية للفصل الدراسى الثانى للعام الجامعى 1440 فى الاسبوع الثانى عشر لكل المواد فى ميعاد المحاضرات

على جميع الطلب احضار الجوالات او الايباد فى المحاضرة



موقع الكلية على مواقع التواصل الاجتماعى











موقع الكلية على ويكيبيديا

WikipediA

محرك بحث





مواقع الجامعات السعودية




























للاشتراك فى المنتدى




منتدى البكتيريا السريرية

موافع المدونة


النتائج


أعزائى الطلبة

تم رصد الدرجات النهائية فى جميع المواد

تفضل بالدخول على البوابة من هنـــــــا


Workshop registration

CLICK ON THE LINK BELOW FOR REGISTRATION


Seminar and Workshop in Blood Bank

 

Scan By Mobile


 

ِApplied Clinical Biocemistry

ِApplied Clinical Microbiology

Clinical Bacteriology

نص

الساعات المكتبية من الاحد الى الخميس من الساعه 12 الى 1 ظهرا

احياة دقيقة طبية

خاص بطلاب ا لاحياء الدقيقة الطبية


المحاضرات


Researchgate

للدخول اضغط 

هنا

.

للدخول اضغط

هنا

.


للتبليغ عن عطل فى السبورة او المنصة

من فضلك قم بتعبئة النموذج بالضغط على الرابط


هنا



المكتبه الرقميه السعوديه

دليل هاتف الجامعه

إحصائية الموقع

عدد الصفحات: 146

البحوث والمحاضرات: 135

الزيارات: 1246462